- Product Categories
- Friendly Links
- home > Supply > The new low-cost supply of Shanghai, Zhejiang Chi net more sample letter tissue grinder Tissuelyser-192 factory outlets
The new low-cost supply of Shanghai, Zhejiang Chi net more sample letter tissue grinder Tissuelyser-192 factory outlets
Information Name: | The new low-cost supply of Shanghai, Zhejiang Chi net more sample letter tissue grinder Tissuelyser-192 factory outlets |
Published: | 2015-01-14 |
Validity: | 360 |
Specifications: | |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | Detailed description of a range of applications 1. For a variety of organizations, including grinding plant roots, stems, leaves, flowers, fruit, seeds and other samples of broken; 2. For a variety of animal tissues including grinding the brain, heart, lungs, stomach, liver, thymus, kidney, intestine, lymph node, muscle, bone and other samples broken; 3. Grinding suitable fungi, bacteria and other samples broken; 4. For food, grinding medicine component analysis to detect broken; 5. Suitable for volatile samples include grinding coal, oil shale, and other samples of broken wax products; 6. For plastic, polymer include grinding PE, PS, textiles, resins and other samples broken. Two product characteristics "Tissuelyser" series grinder using a special vertical up and down vibrate mode, by grinding beads (zirconia, steel, glass beads, ceramic beads) high-frequency reciprocating vibration, impact, shear. Quickly achieve the purpose. The samples were ground with fuller, more uniform, more reproducible sample, no cross contamination of more than 1. The number of operations between the sample, good and efficient work can be done fast effect 2 × 24,2 × 48,4 within 1 minute × 96 samples grinding. Saves time and effort, between batches, small differences in the batch. Protein extracted higher specific activity, nucleic acid fragments longer. 2. No cross-contamination in the fully closed state of the sample tube in the crushing process, can be disposable centrifuge tubes and beads. Samples intact in the tube, avoid cross-contamination and outside contamination between samples. 3. easy to operate 3.1 built-in program controller, polishing time, the rotor vibration frequency and other parameters set; 3.2 user-friendly interface. 4. The stability of vertical oscillation mode 4.1, grinding fuller, better stability; process 4.2 instrument operation, noise less than 70dB, does not interfere with other experiments or equipment. 5. easy to operate when required cryogenic grinding cryogenic environment can be placed samples immersed in liquid nitrogen cooling adapter for 1-2 minutes, remove and quickly moved to the host fixed to start grinding, does not require refrigeration process again, saving the liquid nitrogen . 6. Repeatability of the same tissue sample set the same procedure, to obtain the same grinding effect. Working time is short, the sample temperature does not rise three technical parameters application areas: organizational homogenization, grinding, cell disruption, homogenization, material dispersion, preparation, sample mixing, shaking LCD: microcomputer control big-screen 5.7 "TFT LCD screen show working status of the adapter handle the sample size: 192 * (0.2-0.5ML) / 96 * 2ML / 48 * 2ML / 16 * (7-10) ML / 12 * 15ML / 4 * 25ML / 4 * 50ML standard preparation: can Option two specifications adapter homogeneous speed: 10-70 HZ / sec shockproof principle: German patent schleifen-1 adapter works Material: Teflon grinding way: wet grinding, dry grinding, cryogenic grinding can be a maximum feed size: No, according to the expected size of the adapter to adjust the final: ~ 5μm grind number (the number of admissible jar) platform> 2 fastening device with automatic center positioning when safety lock, full protection of a hard material grinding sets Gang, polytetrafluoroethylene vinyl fluoride (Teflon Long) Power: two-phase 220V / 50HZ Working time: 0 seconds and 99 minutes, the user can set their own; grinding ball diameter: 0.1-30mm grinding balls material: steel, chrome steel, zirconium carbide tungsten, quartz sand; Acceleration: within two seconds to reach maximum speed reducer: lowest speed noise levels in two seconds: <70db Dimensions: 480 * 420 * 575 Weight: 60KG * 1HZ = 30 rev / sec * conventional adapters can be placed in the refrigerator at work in order to give a sample of a cold environment can reprovision with cooling adapter, you can soak in liquid nitrogen for thirty minutes. * random * 1000 5MM stainless steel bulb working environment for noise emissions type value, depending on the sample and the polishing instrument settings. Parameters in the table no-load state is usually used for a small sample of DNA and RNA isolation can be prepared in a disposable centrifuge tube. Teflon material may be made of the adapter , up to 5 or 10 disposable sample tubes, cell disruption. tissue obtained in a fast and efficient multi-sample crushed tissue grinder in a very short period of time, and therefore no additional low temperature refrigeration |
Admin>>>
You are the 19999 visitor
Copyright © GuangDong ICP No. 10089450, New Chi Biotechnology Co., Ltd. Quzhou All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 19999 visitor
Copyright © GuangDong ICP No. 10089450, New Chi Biotechnology Co., Ltd. Quzhou All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility