Detailed Product Description: | JX-2010 frozen mixed ball mills, also known as high-throughput tissue cryopreservation grinder. 1. Plant tissue samples can be ground: roots, stems, leaves, flowers, fruits, seeds, etc. 2. animal tissues: brain, heart, lungs, stomach, liver, thymus, kidney, intestine, lymph nodes, muscles, bones, etc. 3. fungi Bacteria: yeast, E. coli, etc. 4. Food and Drug: all kinds of food, tablet, etc. 5. volatile sample: coal, oil shale, wax products etc. 6. plastics, polymers: PE, PS, textiles, resins and other product characteristics "JX" series grinder using a special vertical up and down motion mode, by grinding beads (zirconia, steel, glass beads, ceramic beads) high-frequency reciprocating vibration, shock, shear. Rapid implementation purposes. The sample was ground with a fuller, more uniform, reproducible sample, there is no cross contamination between samples. 1. The number of operations, good efficient and rapid effect can be done 1.5ml × 48,2ml × 48 in 1 minute, ground samples. Saving time and effort, between batches, small differences in the batch. Higher specific activity extracted proteins, nucleic acid fragments longer. 2. No cross-contamination in the sample tube closed state during crushing, can be disposable centrifuge tubes and beads. Samples intact in the tube, avoid cross-contamination and outside contamination between samples. 3. easy to operate 3.1 built-in program controller, polishing time, the rotor vibration frequency and other parameters set; 3.2 user-friendly interface. The stability 4.1 vertical oscillation mode, ground fuller, better stability; process 4.2 instrument operation, the noise is less than 70dB, will not interfere with other experiments or equipment. 5. easy to operate when required low temperature cryogenic grinding environment can be placed in the sample adapter immersion in liquid nitrogen cooling for 1-2 minutes, remove and quickly moved to the host fixed to start grinding, does not require refrigeration process again, saving the liquid nitrogen . 6. reproducible tissue samples from the same set the same program, to obtain the same grinding effect. Working time is short, the sample temperature does not rise 7. The kit companies supporting a sound animals, plants, microbes and other samples of DNA, RNA and protein extraction kit. Technical parameters ◆ Application: organizations homogenizing, grinding, cell disruption, homogenization, material dispersion, preparation, sample mixing, shaking ◆ LCD: Schneider (Schneider) one for control of the screen, user-friendly design, built-in instructions, in English switching state ◆ real-time monitoring of imported parts assembled: Omron (OMRON) photoelectric sensor, door locks using polymer materials, more reliable and durable transmission ◆: Japan NSK, more stable, durable ◆ Adapter Capacity: 0.2 to 0.5 mL × 48 holes of the adapter; 1.5-2 mL × 48 holes of the adapter; 7 ~ 10 mL × 16 holes of the adapter; 15 mL × 8 hole of the adapter; 25ml × 4 hole of the adapter; 50 mL × 2 hole adapter ◆ Standard configuration: 2ML * 48 adapter and 5ML * 12 adapter (polytetrafluoroethylene material designed for cryogenic grinding rapid design, withstand temperatures as low as -80 degrees and liquid nitrogen cryogenic treatment, the greatest degree of protection sample activity) ◆ Homogeneous Speed: 10-70 HZ, 300-2100 beats / min ◆ Earthquake principle: schleifen-1 adapter works ◆ Material: Teflon or steel ◆ grinding way: Wet grinding, dry grinding, cryogenic grinding can ◆ maximum intake feed size: No, according to the adapter ◆ adjust the final discharge size: ~ 5μm ◆ the number of platforms grinding (milling admissible number of cans)> fastening means 2 ◆ with automatic centering is when ◆ safety lock, full protection ◆ grind Kit materials just hard, polytetrafluoroethylene (Teflon-long) ◆ Power: two-phase 220V / 50HZ ◆ Working Hours: -9999 minutes 0 seconds, the user can set their own; ◆ grinding ball diameter: 0.1-30mm ◆ grinding balls material: steel, chrome steel, zirconia, tungsten carbide, quartz sand; ◆ Speed: maximum speed ◆ within 2 seconds slow: the lowest speed ◆ noise level within two seconds: <70db ◆ Dimensions: 370 × 360 × 520 mm; ◆ Weight: 30KG Special Note * 1HZ = 30 rev / sec * Conventional adapter can be placed in the refrigerator in order to work, when to sample a cold environment. Adapter comes with refrigeration, you can soak in liquid nitrogen for thirty minutes. * Random 1000 6MM stainless steel balls. * For the work environment noise emission values, depending on the type and Mills set of samples. Parameters in the table no-load condition. * Generally small sample for DNA and RNA isolation can be prepared in a disposable centrifuge tube. Adapters can be made of PTFE, up to 5 or 10 disposable sample tubes, cell disruption. Tissue rapidly and effectively broken in a very short period of time in a multi-sample tissue mill, eliminating the need for additional low-temperature cooling. |
Admin>>>
You are the 19999 visitor
Copyright © GuangDong ICP No. 10089450, New Chi Biotechnology Co., Ltd. Quzhou All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 19999 visitor
Copyright © GuangDong ICP No. 10089450, New Chi Biotechnology Co., Ltd. Quzhou All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility